The Production of Hydroxyapatite Standards, Used for Post CBCT Scan Hounsfield Unit Calibration

Varghai, Kaveh, Varghai

Abstract Details

, Master of Sciences, Case Western Reserve University, Biomedical Engineering.
We think that we can help ease patients’ concerns by altering diagnostic x-rays. Our goal is to use CT information to pre-surgically determine the likelihood of success of an operation. This technique could help expectation setting or, moreover, could help oral physicians make procedural decisions which result in higher rates of implant stability and functionality. Currently, cone beam computerized tomographies (CBCT) are commonly used in the dental community for morphological assessment of the mandible and maxilla. Previous studies have shown the potential of using a single set of phantoms in the oral cavity, to derive Hounsfield Units (HU). However, due to the polychromatic x-ray source in CBCT scanners, variation in average grey level for a single phantom exists, as a function of location. This thesis will focus on using common biomaterials, used in biomedical implants, to design and fabricate a set of standards, small enough so that a single set is fixed adjacent to the region of interest (ROI). This set of phantoms would allow dental clinicians to quantitatively assess bone quality by ultimately comparing derived HU to mass density without the need for expensive medical software.
Steven Eppell, Ph.D (Advisor)
Russell Wang, DDS, MSD (Committee Member)
David Wilson, Ph.D (Committee Member)

Recommended Citations

Citations

  • Varghai, Varghai, K. (n.d.). The Production of Hydroxyapatite Standards, Used for Post CBCT Scan Hounsfield Unit Calibration [Master's thesis, Case Western Reserve University]. OhioLINK Electronic Theses and Dissertations Center. http://rave.ohiolink.edu/etdc/view?acc_num=case1505842174493682

    APA Style (7th edition)

  • Varghai, Varghai, Kaveh. The Production of Hydroxyapatite Standards, Used for Post CBCT Scan Hounsfield Unit Calibration. Case Western Reserve University, Master's thesis. OhioLINK Electronic Theses and Dissertations Center, http://rave.ohiolink.edu/etdc/view?acc_num=case1505842174493682.

    MLA Style (8th edition)

  • Varghai, Varghai, Kaveh. "The Production of Hydroxyapatite Standards, Used for Post CBCT Scan Hounsfield Unit Calibration." Master's thesis, Case Western Reserve University. Accessed MAY 05, 2024. http://rave.ohiolink.edu/etdc/view?acc_num=case1505842174493682

    Chicago Manual of Style (17th edition)