Skip to Main Content
Frequently Asked Questions
Submit an ETD
Global Search Box
Need Help?
Keyword Search
Participating Institutions
Advanced Search
School Logo
Files
File List
osu1192823756.pdf (10.99 MB)
ETD Abstract Container
Abstract Header
Chattering suppression in sliding mode control system
Author Info
Lee, Hoon
Permalink:
http://rave.ohiolink.edu/etdc/view?acc_num=osu1192823756
Abstract Details
Year and Degree
2007, Doctor of Philosophy, Ohio State University, Mechanical Engineering.
Abstract
In this dissertation, various known methods to decrease level of chattering caused by unmodeled dynamics are reviewed. And an analysis to understand system behavior in the presence of such unmodeled dynamics and to estimate the amplitude and frequency of chattering using describing function is provided. It is shown that the amplitude is proportional to relay gain of discontinuous control, and the frequency is inversely proportional to the time constant of unmodeled dynamics. Two methods are proposed to change switching magnitude of sliding mode control to reduce chattering. Based on the original idea of Variable Structure System, first method is to use adaptive relay gain which depends on system states. Second method varies switching gain of sliding mode control along the equivalent control. System behaviors with the two controller designs are analyzed, and it is demonstrated by simulations that chattering can be significantly reduced. For systems controlled by on/off switches or fixed switching gain only, chattering also appears if switching frequency is restricted at a finite value. To suppress chattering in such case, a methodology based on the harmonic cancellation is proposed. To fix switching frequency and to obtain desired phase shift between any two consecutive phases, hysteresis loops with adaptive width are implemented in switching elements. The design principle and procedure of the methodology are suggested, and chattering reduction effect of the method is demonstrated by various simulation results. It is also shown that the method using multiple phases may decrease chattering caused by unmodeled dynamics as well with the equivalent width of hysteresis which makes entire phases have the same frequency.
Committee
Vadim Utkin (Advisor)
Keywords
Sliding Mode Control
;
Sliding Mode
;
Chattering
;
Ripple
;
Power Converter
Recommended Citations
Refworks
EndNote
RIS
Mendeley
Citations
Lee, H. (2007).
Chattering suppression in sliding mode control system
[Doctoral dissertation, Ohio State University]. OhioLINK Electronic Theses and Dissertations Center. http://rave.ohiolink.edu/etdc/view?acc_num=osu1192823756
APA Style (7th edition)
Lee, Hoon.
Chattering suppression in sliding mode control system.
2007. Ohio State University, Doctoral dissertation.
OhioLINK Electronic Theses and Dissertations Center
, http://rave.ohiolink.edu/etdc/view?acc_num=osu1192823756.
MLA Style (8th edition)
Lee, Hoon. "Chattering suppression in sliding mode control system." Doctoral dissertation, Ohio State University, 2007. http://rave.ohiolink.edu/etdc/view?acc_num=osu1192823756
Chicago Manual of Style (17th edition)
Abstract Footer
Document number:
osu1192823756
Download Count:
9,578
Copyright Info
© 2007, all rights reserved.