Skip to Main Content
Frequently Asked Questions
Submit an ETD
Global Search Box
Need Help?
Keyword Search
Participating Institutions
Advanced Search
School Logo
Files
File List
osu1316482714.pdf (46.48 MB)
ETD Abstract Container
Abstract Header
Fabrication and testing of micro-cantilevers in bovine cortical bone
Author Info
Ramesh, Pravin K.
Permalink:
http://rave.ohiolink.edu/etdc/view?acc_num=osu1316482714
Abstract Details
Year and Degree
2011, Master of Science, Ohio State University, Mechanical Engineering.
Abstract
The use of focused ion beam (FIB) for machining micro-cantilevers for Mechanical testing of bone at small length-scales is investigated. Bone is a multi-layered, multi-scale composite made up of distinct constituents at different size scales. The aim of this project is to measure the mechanical properties of these individual components through bending experiments, in order to model the aggregate behavior under conditions such as age or disease. Microcantilevers with dimensions on the order of 10 microns were selectively machined within microstructural regions of interest, such as osteons. The load-displacement response under a variety of test conditions was then obtained using a modified nanoindenter. Elastic modulus measurements of wet and dry bovine cortical bone are in agreement with bulk measurements. Load relaxation experiments reveal two relaxation time constants which we hypothesize to be associated with rearrangements happening within the organic phase and the discharge of water, respectively.
Committee
Katharine Flores, PhD (Advisor)
Peter Anderson, PhD (Committee Member)
Subject Headings
Biomechanics
;
Materials Science
;
Mechanical Engineering
Recommended Citations
Refworks
EndNote
RIS
Mendeley
Citations
Ramesh, P. K. (2011).
Fabrication and testing of micro-cantilevers in bovine cortical bone
[Master's thesis, Ohio State University]. OhioLINK Electronic Theses and Dissertations Center. http://rave.ohiolink.edu/etdc/view?acc_num=osu1316482714
APA Style (7th edition)
Ramesh, Pravin.
Fabrication and testing of micro-cantilevers in bovine cortical bone.
2011. Ohio State University, Master's thesis.
OhioLINK Electronic Theses and Dissertations Center
, http://rave.ohiolink.edu/etdc/view?acc_num=osu1316482714.
MLA Style (8th edition)
Ramesh, Pravin. "Fabrication and testing of micro-cantilevers in bovine cortical bone." Master's thesis, Ohio State University, 2011. http://rave.ohiolink.edu/etdc/view?acc_num=osu1316482714
Chicago Manual of Style (17th edition)
Abstract Footer
Document number:
osu1316482714
Download Count:
141
Copyright Info
© 2011, all rights reserved.