Abstract
A comprehensive study of a micro Open Parallel Plate System (µOPPS) is presented. A detailed 3-dimensional computer model that solves a mass balance equation of a solute within the microchannel in the µOPPS was developed. The behavior of the µOPPS was modeled to determine optimal configuration and operating conditions. It was found that the microchannel width is the most important parameter that influences the performance of the µOPPS - microchannels with a width of 20 µm or less offer excellent performances. For deep channels, performance is essentially independent of channel depth. The capabilities of the µOPPS for preparative applications have also been studied. The µOPPS simulator was extended to model multicomponent systems and nonlinear behavior, and the potential for concentration of trace-species has been explored. By increasing the depth-to-width ratio of the µOPPS, it was possible to increase product-throughput significantly. Additionally, the utility of the µOPPS as a tool for obtaining equilibrium data for protein-salt systems has been investigated. Predictions of isotherm data were made by using the chromatographic-based H-Root Method (HRM). Simulations of the performance of the µOPPS for protein-salt systems in combination with the HRM allowed predicting isotherm coefficients with excellent accuracy, when the appropriate operating conditions were selected. An evaluation of the potential of combining µOPPS with Electrochemically Modulated Liquid Chromatography (EMLC) was also performed. In EMLC the retention of the solutes is modulated by applying an electric potential to a conductive stationary phase. The separation of two proteins by means of electrostatic interactions was simulated. It was found that excellent resolution and capacity factors can be achieved by utilizing narrow microchannels with higher applied potentials. The combination of the µOPPS with EMLC opens up the possibility of a new type of micro separation system with enormous potential for analytical and preparative applications. The study and development of the µOPPS device will offer important advantages for chromatographic separation processes. Future applications of this microsystem can be expected in analytical and preparative modes of chromatography, including design and scale-up of separation systems for pharmaceutical, biological and environmental applications.
Committee
Dr. Neville G. Pinto (Advisor)
Pages
372 p.
Subject Headings
Chemistry, Analytical
Keywords
micro open parallel plate system
;
liquid chromatography
;
MEMS
;
microchromatograph
;
microseparator
Recommended Citations
Refworks
EndNote
RIS
Mendeley
Citations
LAPIZCO-ENCINAS, B. H. (2003).
MICRO OPEN PARALLEL PLATE SEPARATOR: PERFORMANCE AND APPLICATIONS
[Doctoral dissertation, University of Cincinnati]. OhioLINK Electronic Theses and Dissertations Center. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1046966166
APA Style (7th edition)
LAPIZCO-ENCINAS, BLANCA.
MICRO OPEN PARALLEL PLATE SEPARATOR: PERFORMANCE AND APPLICATIONS.
2003. University of Cincinnati, Doctoral dissertation.
OhioLINK Electronic Theses and Dissertations Center
, http://rave.ohiolink.edu/etdc/view?acc_num=ucin1046966166.
MLA Style (8th edition)
LAPIZCO-ENCINAS, BLANCA. "MICRO OPEN PARALLEL PLATE SEPARATOR: PERFORMANCE AND APPLICATIONS." Doctoral dissertation, University of Cincinnati, 2003. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1046966166
Chicago Manual of Style (17th edition)
Abstract Footer
Document number:
ucin1046966166
Download Count:
1,259
Copyright Info
© 2003, all rights reserved.
This open access ETD is published by University of Cincinnati and OhioLINK.