Skip to Main Content
 

Global Search Box

 
 
 
 

ETD Abstract Container

Abstract Header

Oxygen and Carbon Dioxide Levels During Qualitative Respirator Fit Testing

Laferty, Edward Alan

Abstract Details

2004, MS, University of Cincinnati, Medicine : Industrial Hygiene (Environmental Health).
Approved Occupational Safety and Health Administration qualitative respirator fit test methods require the use of a test hood about the subject’s head and shoulders. Workers fit tested by this method have commented on the discomfort of being inside the test enclosure. This study was designed to quantify some parameters that might lead to these types of comments. For this study, subjects performed a series of four respirator fit tests. A quantitative and a qualitative fit test were performed with a full facepiece respirator. Then a quantitative and a qualitative fit test were performed with an N95 filtering facepiece respirator. Parameters measured include: subjects height, weight, and age, oxygen and carbon dioxide levels, air temperature, heart rate, arterial oxygen saturation, and Borg Ratio Scale value on breathing exertion. Carbon dioxide levels are significantly higher and oxygen levels are significantly lower in the respirator when the test hood is used during the qualitative fit test. The temperature inside the test hood rose an average 7.5°F in the course of the qualitative fit test of the N95 filtering facepiece device. These stressors are not present during a quantitative respirator fit test. Professionals conducting respirator fit tests should be aware of the physiological burdens that may occur during the qualitative respirator fit test. Some groups may be especially sensitive to this test such as the elderly, pregnant women, persons with pulmonary and/or cardiac disease, or persons with psychological disorders such as anxiety, panic disorders, or claustrophobia.
Dr. Roy McKay (Advisor)
50 p.

Recommended Citations

Citations

  • Laferty, E. A. (2004). Oxygen and Carbon Dioxide Levels During Qualitative Respirator Fit Testing [Master's thesis, University of Cincinnati]. OhioLINK Electronic Theses and Dissertations Center. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1086808006

    APA Style (7th edition)

  • Laferty, Edward. Oxygen and Carbon Dioxide Levels During Qualitative Respirator Fit Testing. 2004. University of Cincinnati, Master's thesis. OhioLINK Electronic Theses and Dissertations Center, http://rave.ohiolink.edu/etdc/view?acc_num=ucin1086808006.

    MLA Style (8th edition)

  • Laferty, Edward. "Oxygen and Carbon Dioxide Levels During Qualitative Respirator Fit Testing." Master's thesis, University of Cincinnati, 2004. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1086808006

    Chicago Manual of Style (17th edition)