Skip to Main Content
Frequently Asked Questions
Submit an ETD
Global Search Box
Need Help?
Keyword Search
Participating Institutions
Advanced Search
School Logo
Files
File List
akron1226615129.pdf (3.41 MB)
ETD Abstract Container
Abstract Header
Efficacy of a Multi-Channel Array Coil for Pediatric Cardiac Magnetic Resonance Imaging
Author Info
Ravi, Anandh
Permalink:
http://rave.ohiolink.edu/etdc/view?acc_num=akron1226615129
Abstract Details
Year and Degree
2008, Master of Science in Engineering, University of Akron, Biomedical Engineering.
Abstract
Pediatric MR imaging currently uses adult RF coils which reduces the quality of pediatric images considering the large field of view and low signal to noise ratio (SNR). Thus there is a growing need for developing and evaluating specialty coils targeting pediatric patients. The current study focused on the design, development and evaluation of infant cardiac array RF local coil for magnetic resonance imaging of the heart of infant patients. The design criteria were identified and the coil was designed taking into account the safety considerations for the targeted patient population. This study successfully evaluated the performance of the infant cardiac array RF coil based on two most significant MR imaging parameters, SNR and imaging resolution, on a 1.5T commercial MR scanner. The increase in SNR and improvement in the resolution of images using the infant cardiac array over an existing commercially available adult coil was established using different kinds of phantom (7L, 2L, orange and lime) studies. The results revealed that there was an increase of 140% in SNR using infant cardiac array compared to the commercially available adult coil and the high resolution (<200 microns) images obtained confirmed the efficacy of the infant cardiac array coil. Thus, the infant cardiac array RF coil provides enhanced performance and high quality MR images for infant clinical applications compared to the commercial adult coils.
Committee
Narender P. Reddy, PhD (Advisor)
Daniel B. Sheffer, PhD (Advisor)
Subject Headings
Biomedical Research
;
Engineering
;
Health Care
;
Radiology
;
Scientific Imaging
Keywords
RF coil
;
MRI
;
Cardiac
;
Infant cardiac imaging
;
Radiology
;
Magnetic Resonance Imaging
;
Infant cadiac array
;
Recommended Citations
Refworks
EndNote
RIS
Mendeley
Citations
Ravi, A. (2008).
Efficacy of a Multi-Channel Array Coil for Pediatric Cardiac Magnetic Resonance Imaging
[Master's thesis, University of Akron]. OhioLINK Electronic Theses and Dissertations Center. http://rave.ohiolink.edu/etdc/view?acc_num=akron1226615129
APA Style (7th edition)
Ravi, Anandh.
Efficacy of a Multi-Channel Array Coil for Pediatric Cardiac Magnetic Resonance Imaging.
2008. University of Akron, Master's thesis.
OhioLINK Electronic Theses and Dissertations Center
, http://rave.ohiolink.edu/etdc/view?acc_num=akron1226615129.
MLA Style (8th edition)
Ravi, Anandh. "Efficacy of a Multi-Channel Array Coil for Pediatric Cardiac Magnetic Resonance Imaging." Master's thesis, University of Akron, 2008. http://rave.ohiolink.edu/etdc/view?acc_num=akron1226615129
Chicago Manual of Style (17th edition)
Abstract Footer
Document number:
akron1226615129
Download Count:
1,782
Copyright Info
© 2008, all rights reserved.
This open access ETD is published by University of Akron and OhioLINK.