Skip to Main Content
Frequently Asked Questions
Submit an ETD
Global Search Box
Need Help?
Keyword Search
Participating Institutions
Advanced Search
School Logo
Files
File List
akron1342814846.pdf (1.12 MB)
ETD Abstract Container
Abstract Header
A Novel Technique to Improve the Resolution of a Gamma Camera
Author Info
Natarajamani, Deepa
Permalink:
http://rave.ohiolink.edu/etdc/view?acc_num=akron1342814846
Abstract Details
Year and Degree
2012, Master of Science in Engineering, University of Akron, Biomedical Engineering.
Abstract
Nuclear medicine images have limited spatial resolution because of the limitations in the radiation detector and the associated electronics. Due to these limitations, the image of a point source of radiation is blurred. The degree of this blurring is called the point spread function of a gamma camera, the imaging device used in nuclear medicine. The aim of this study is to develop a technique to increase the spatial resolution and contrast by improving the point spread function of the system. The basic idea of the proposed technique is to build a special collimator plate that replaces the conventional gamma camera collimator. Develop an algorithm that processes the images obtained with a gamma camera with the special collimator plate to improve the point spread function of the gamma camera. The images with the proposed gamma camera collimator plate method will be compared to the conventional collimator method. Qualitatively the comparison is done by visually inspecting the images. Quantitative comparisons are done by the significant differences in their modulation transfer function. Both comparisons indicate the proposed method is better than the conventional method.
Committee
Dale Mugler, Dr. (Advisor)
Anthony Passalaqua, Dr. (Advisor)
Daniel Sheffer, Dr. (Committee Member)
Pages
60 p.
Subject Headings
Biomedical Engineering
Keywords
Image processing
;
SPECT Imaging
;
spatial resolution
;
Nuclear medicine
;
Iterative reconstruction
;
MLEM
Recommended Citations
Refworks
EndNote
RIS
Mendeley
Citations
Natarajamani, D. (2012).
A Novel Technique to Improve the Resolution of a Gamma Camera
[Master's thesis, University of Akron]. OhioLINK Electronic Theses and Dissertations Center. http://rave.ohiolink.edu/etdc/view?acc_num=akron1342814846
APA Style (7th edition)
Natarajamani, Deepa.
A Novel Technique to Improve the Resolution of a Gamma Camera.
2012. University of Akron, Master's thesis.
OhioLINK Electronic Theses and Dissertations Center
, http://rave.ohiolink.edu/etdc/view?acc_num=akron1342814846.
MLA Style (8th edition)
Natarajamani, Deepa. "A Novel Technique to Improve the Resolution of a Gamma Camera." Master's thesis, University of Akron, 2012. http://rave.ohiolink.edu/etdc/view?acc_num=akron1342814846
Chicago Manual of Style (17th edition)
Abstract Footer
Document number:
akron1342814846
Download Count:
2,674
Copyright Info
© 2012, all rights reserved.
This open access ETD is published by University of Akron and OhioLINK.