A Comparative Image Quality Analysis between Multi-Slice Computed Tomography and Cone Beam Computed Tomography for Radiation Treatment Planning Purposes

Fentner, David A

Abstract Details

2013, Master of Science in Biomedical Sciences (MSBS), University of Toledo, College of Medicine.
The ability of an imaging system to accurately identify patient anatomy and provide reliable tumor information is critical in the radiation treatment planning process. As image guided radiation therapy and adaptive radiation therapy become more prevalent in treatment procedures, the image quality of these systems could perhaps be a limiting factor in their effectiveness. This research is intended to explore the differences in image quality between two separate imaging modalities commonly used in radiation therapy. A Philips Gemini TF Big Bore PET/CT and Varian True Beam On-Board kV cone beam CT imager were both assessed using the Catphan 504 image quality phantom. Ten different tests were evaluated with the phantom using several routine imaging protocols from both systems. Overall, the image quality between the cone beam and CT system was fairly consistent with one another with the exception of the low contrast detectability measurements. The effects of scatter radiation and image noise significantly reduced the cone beams ability to detect low contrast objects which ultimately degraded its image quality compared to CT.
Michael Dennis, PhD (Committee Chair)
Ishmael Parsai, PhD (Committee Member)
Dianna Shydka, PhD (Committee Member)
93 p.

Recommended Citations

Citations

  • Fentner, D. A. (2013). A Comparative Image Quality Analysis between Multi-Slice Computed Tomography and Cone Beam Computed Tomography for Radiation Treatment Planning Purposes [Master's thesis, University of Toledo]. OhioLINK Electronic Theses and Dissertations Center. http://rave.ohiolink.edu/etdc/view?acc_num=mco1372413982

    APA Style (7th edition)

  • Fentner, David. A Comparative Image Quality Analysis between Multi-Slice Computed Tomography and Cone Beam Computed Tomography for Radiation Treatment Planning Purposes. 2013. University of Toledo, Master's thesis. OhioLINK Electronic Theses and Dissertations Center, http://rave.ohiolink.edu/etdc/view?acc_num=mco1372413982.

    MLA Style (8th edition)

  • Fentner, David. "A Comparative Image Quality Analysis between Multi-Slice Computed Tomography and Cone Beam Computed Tomography for Radiation Treatment Planning Purposes." Master's thesis, University of Toledo, 2013. http://rave.ohiolink.edu/etdc/view?acc_num=mco1372413982

    Chicago Manual of Style (17th edition)