Skip to Main Content
Frequently Asked Questions
Submit an ETD
Global Search Box
Need Help?
Keyword Search
Participating Institutions
Advanced Search
School Logo
Files
File List
toledo1122671274.pdf (1.06 MB)
ETD Abstract Container
Abstract Header
Development of an Implantable Data Acquisition System
Author Info
Sonalkar, Prachi Santosh
Permalink:
http://rave.ohiolink.edu/etdc/view?acc_num=toledo1122671274
Abstract Details
Year and Degree
2005, Master of Science in Bioengineering, University of Toledo, Bioengineering.
Abstract
Implantable medical devices offer several fascinating possibilities for improving human health. Coupled with advancements in the miniaturization of electronic systems, the array of implantable medical devices will continue to expand. Furthermore, if instrumentation based implants are interfaced to a communication sub-system, the potential exists for wireless microcontroller software updates and real-time data acquisition from integrated sensors which could relay patient health information or implant mechanical conditions to an external system. This thesis focuses on development of such a platform. The current system incorporates a Radio Frequency (RF) telemetry system integrated to an embedded microcontroller with multi-channel data acquisition capabilities. This system employs a XE1201A (Xemics Inc, Switzerland) transceiver chipset providing a bi-directional 405 MHz RF communications link. This transceiver is integrated to an ultra-low power MSP430F149 (Texas Instruments, Dallas TX) microcontroller with 12-bit analog to digital capabilities. In addition, a similar external system is interfaced to a PC for complete control and real-time data acquisition is developed, a custom developed script language is implemented to input required commands for collection of desired data from a particular sensor. The software code and protocol to establish bi-directional communication was developed in ANSI C which is implemented on the microcontroller and the PC interface was developed using LabVIEW (National Instruments, Austin TX). In addition, all ASICs are available in die form to allow for ultra-miniaturization. The system is in the process of being evaluated in a spinal disc implant equipped with strain and temperature sensors. Future work will involve manufacturing the entire system in an ultra-compact package through the use of flip-chip technology.
Committee
Brent Cameron (Advisor)
Pages
137 p.
Keywords
Medical Implants
;
Data Acquisition
;
Wireless Communication
;
RF Telemetry
Recommended Citations
Refworks
EndNote
RIS
Mendeley
Citations
Sonalkar, P. S. (2005).
Development of an Implantable Data Acquisition System
[Master's thesis, University of Toledo]. OhioLINK Electronic Theses and Dissertations Center. http://rave.ohiolink.edu/etdc/view?acc_num=toledo1122671274
APA Style (7th edition)
Sonalkar, Prachi.
Development of an Implantable Data Acquisition System.
2005. University of Toledo, Master's thesis.
OhioLINK Electronic Theses and Dissertations Center
, http://rave.ohiolink.edu/etdc/view?acc_num=toledo1122671274.
MLA Style (8th edition)
Sonalkar, Prachi. "Development of an Implantable Data Acquisition System." Master's thesis, University of Toledo, 2005. http://rave.ohiolink.edu/etdc/view?acc_num=toledo1122671274
Chicago Manual of Style (17th edition)
Abstract Footer
Document number:
toledo1122671274
Download Count:
1,190
Copyright Info
© 2005, all rights reserved.
This open access ETD is published by University of Toledo and OhioLINK.